Products

Find the artificial intelligence based software for radiology that you are looking for.
All products listed are available for the European market (CE marked).

19/211 results

Logo
Subspeciality: Cardiac, Vascular
Modality: CT

Automatic measurement of aortic diameter, longitudinal comparison using prior exams

ARVA, “Augmented Radiology for Vascular Aneurysm“, is a solution for automatic measurement of the maximum transverse diameter of the aorta. ARVA provides the aortic maximum diameter, external wall ...

CE:
Class IIa - MDR
Logo
FDA:
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Cardiac
Modality: CT

FFRCT values along coronary vessels

The HeartFlow Analysis is a coronary physiologic simulation software for the clinical quantitative and qualitative analysis of previously acquired Computed Tomography DICOM data for clinically stable ...

CE:
Class IIa - MDD
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Neuro, Cardiac, MSK, Chest, Abdomen, Breast
Modality: MR

MRI scan acceleration, MRI image enhancement

SwiftMR aims to accelerate MRI scans by up to 50% by enhancing low-quality initial outputs from accelerated scans. The deep-learning model improves SNR and resolution of MRI inputs, irrespective of ...

CE:
Class IIa - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Cardiac
Modality: Ultrasound

Automated measurements include 2-dimensional (cardiac volumes, all 4 chambers of the heart), M-mode ...

Us2.ai supports cardiovascular disease diagnostics by providing machine learning based solutions that analyze and interpret echocardiograms, which are ultrasound images of the heart, creating patient ...

CE:
Class IIb - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Cardiac
Modality: MR

Automated analysis of function, flow, myocardial perfusion, patent foramen ovale, strain, T1 ...

suiteHEART® Software is intended to assist trained clinical personnel in the qualification and quantification of cardiac function. The software provides the tools to adjust the parameters of the ...

CE:
Class IIa - MDD
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Neuro, Cardiac, MSK, Chest, Abdomen
Modality: CT

CT Image denoising for any body part

ClariCT.AI is an AI-powered CT image denoising solution to provide increased image clarity in CT examinations with excessive image noise due to either low dose or large patient. It is trained to work ...

CE:
Class IIa - MDD
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Chest, Abdomen, Cardiac, Vascular
Modality: CT

Abdominal aortic aneurysm and aortic dissection (type A and B) detection, notification

Viz AORTIC provides automatic detection of suspected abdominal aortic aneurysm and aortic dissection.

CE:
Class I - MDD
Logo
FDA:
Logo
Information source:
Public
Certification verified:
No
Logo
Subspeciality: Cardiac
Modality: CT

Stenosis classification according to CAD-RADS, FFR-AI prediction per coronary, confidence score, ...

CorEx is artificial intelligence software for cardiac imaging. It prioritizes at-risk patients. It automatically analyzes coronary CT images (CCTA) images independently detecting and classifying ...

CE:
Class I - MDD
Logo
FDA:
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Cardiac
Modality: MR

Automatic segmentation, volume quantification and length measurement of the heart chambers, strain ...

QIR-MR is a clinical decision support software for the diagnosis, treatment, prevention, or mitigation of cardiovascular conditions. It allows quantitative analyses of cardiovascular Magnetic ...

CE:
Class IIa - MDD
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Cardiac
Modality: MR

Heart ventricles segmentation, quantification of ventricular volumes, myocardial mass, and ejection ...

The AI4CMR software performs a automatic cardiac segmentation and interpretation of Cardiac Magnetic Resonance (CMR), allowing quantification of various parameters without the need for intervention ...

CE:
Class IIa - MDR
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
Yes
Logo
Subspeciality: Cardiac
Modality: Ultrasound

Ejection Fraction, Left Ventricle global and segmental strain, Left Ventricle segmental wall ...

LVivo AI Cardiac ultrasound analysis solutions provide objective cardiac ultrasound images analysis, aimed at mitigating the challenges of manually capturing and visually analyzing ultrasound images.

CE:
Class IIa - MDD
Logo
FDA:
Class II
Logo
Information source:
Vendor
Certification verified:
No
Logo
Subspeciality: Cardiac
Modality: Ultrasound

Volume quantification, area quantification, distance quantification, disease recognition, Doppler ...

Ligence has developed a platform for automated analysis and reporting of 2D transthoracic echocardiography studies. The Ligence Heart platform reads DICOM format data, recognises image views, heart ...

CE:
Class IIa - MDR
Logo
FDA:
Logo
Information source:
Vendor
Certification verified:
Yes